Sensitivity and specificity of blood cobalt and chromium metal ions for predicting failure of metal-on-metal hip replacement

Author:

Hart A. J.1,Sabah S. A.1,Bandi A. S.1,Maggiore P.1,Tarassoli P.1,Sampson B.1,A. Skinner J.2

Affiliation:

1. Imperial College London, Department of Musculoskeletal Surgery, Charing Cross Hospital Campus, Fulham Palace Road, London W6 8RF, UK.

2. Royal National Orthopaedic Hospital, Brockley Hill, Stanmore, Middlesex HA7 4LP, UK.

Abstract

Blood metal ions have been widely used to investigate metal-on-metal hip replacements, but their ability to discriminate between well-functioning and failed hips is not known. The Medicines and Healthcare products Regulatory Agency (MHRA) has suggested a cut-off level of 7 parts per billion (ppb). We performed a pair-matched, case-control study to investigate the sensitivity and specificity of blood metal ion levels for diagnosing failure in 176 patients with a unilateral metal-on-metal hip replacement. We recruited 88 cases with a pre-revision, unexplained failed hip and an equal number of matching controls with a well-functioning hip. We investigated the 7 ppb cut-off level for the maximum of cobalt or chromium and determined optimal mathematical cut-off levels from receiver-operating characteristic curves. The 7 ppb cut-off level for the maximum of cobalt or chromium had a specificity of 89% and sensitivity 52% for detecting a pre-operative unexplained failed metal on metal hip replacement. The optimal cut-off level for the maximum of cobalt or chromium was 4.97 ppb and had sensitivity 63% and specificity 86%. Blood metal ions had good discriminant ability to separate failed from well-functioning hip replacements. The MHRA cut-off level of 7 ppb provides a specific test but has poor sensitivity.

Publisher

British Editorial Society of Bone & Joint Surgery

Subject

Orthopedics and Sports Medicine,Surgery

Reference23 articles.

1. The Epidemiology of Bearing Surface Usage in Total Hip Arthroplasty in the United States

2. No authors listed. National Joint Registry for England and Wales: 5th annual report. 2008:78. www.njrcentre.org.uk (date last accessed 11 January 2011).

3. MRI of early symptomatic metal-on-metal total hip arthroplasty: a retrospective review of radiological findings in 20 hips

4. No authors listed. Medicines and Healthcare products Regulatory Agency (MHRA). Medical Device Alert: all metal-on-metal (MOM) hip replacements, 2010 MDA/2010/033. http://www.mhra.gov.uk/Publications/Safetywarnings/MedicalDeviceAlerts/CON079157 (date last accessed 22 June 2011).

5. The painful metal-on-metal hip resurfacing