A comparison of the effect of large and small metal-on-metal bearings in total hip arthroplasty on metal ion levels and the incidence of pseudotumour

Author:

Ando W.1,Yasui H.1,Yamamoto K.1,Oinuma K.2,Tokunaga H.3,Inaba Y.4,Kobayashi N.4,Aihara M.5,Nakanishi R.6,Ohzono K.1

Affiliation:

1. Department of Orthopaedic Surgery, Kansai Rosai Hospital, Amagasaki, Japan.

2. Funabashi Orthopaedic Hospital, Funabashi, Japan

3. Department of Orthopaedic Surgery, Kansai Medical University Medical Center, Moriguchi, Japan.

4. Department of Orthopaedic Surgery, Yokohama City University, Yokohama, Japan.

5. Department of Orthopaedic Surgery, Aihara Hospital, Minoh, Japan.

6. Department of Orthopaedic Surgery, Showa University, Fujigaoka Hospital, Yokohama, Japan.

Abstract

Aims The purpose of this study was to compare two different types of metal-on-metal (MoM) bearing for total hip arthroplasty (THA): one with a large femoral head (38 mm to 52 mm) and the other with a conventional femoral head (28 mm or 32 mm). We compared clinical outcome, blood metal ion levels, and the incidence of pseudotumour in the two groups. Patients and Methods Between December 2009 and December 2011, 62 patients underwent MoM THA with a large femoral head (Magnum group) and 57 patients an MoM THA with a conventional femoral head (conventional group). Clinical outcome was assessed using the Harris Hip score, University of California, Los Angeles (UCLA) activity score and EuroQol-5D (EQ-5D). Blood metal ion levels were measured and MRI scans were analyzed at a minimum of five years postoperatively. Results No acetabular component was implanted with more than 50° of inclination in either group. The Harris Hip Score, UCLA activity score, and EQ-5D improved postoperatively in both groups; no significant clinical differences were noted between the groups. The blood cobalt ion levels in the conventional group continued to rise postoperatively to five years while reaching a plateau at two years postoperatively in the Magnum group. At five years, the mean cobalt ion level of 1.16 μg/l (sd 1.32) in the Magnum group was significantly lower than the 3.77 μg/l (sd 9.80) seen in the conventional group (p = 0.0015). The incidence of moderate to severe pseudotumour was 4.7% in the Magnum group and 20.6% in the conventional group. There were no dislocations in the Magnum group and two in the conventional group. One patient in the Magnum group underwent revision for pseudotumour at 4.7 years postoperatively. Conclusion At five years, a well-positioned large head MoM THA has a significantly lower level of metal ion release and a lower incidence of moderate to severe pseudotumour than a MoM bearing of conventional size. Cite this article: Bone Joint J 2018;100-B:1018–24.

Publisher

British Editorial Society of Bone & Joint Surgery

Subject

Orthopedics and Sports Medicine,Surgery

Reference19 articles.

1. Larger Diameter Bearings Reduce Wear in Metal-on-Metal Hip Implants

2. Early failure of metal-on-metal bearings in hip resurfacing and large-diameter total hip replacement

3. Pseudotumours associated with metal-on-metal hip resurfacings

4. Metal-on-Metal Bearings and Hypersensitivity in Patients with Artificial Hip Joints

5. No authors listed. Medical device alert (MDA/2012/036): All metal-on-metal (MoM) hip replacements. Medicines and Healthcare products Regulatory Agency (MHRA), 25 June 2012. http://www.mhra.gov.uk/home/groups/dts-bs/documents/medicaldevicealert/ con155767.pdf (date last accessed 17 May 2018).

Cited by 14 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3