Low-dose radiation with 80-kVp computed tomography to diagnose pulmonary embolism: a feasibility study

Author:

Nyman Ulf1,Björkdahl Peter2,Olsson Marie-Louise3,Gunnarsson Mikael3,Goldman Bitte4

Affiliation:

1. Department of Radiology, University of Lund, Lasarettet Trelleborg, Trelleborg;

2. Department of Radiology, Lasarettet Trelleborg, Trelleborg;

3. Medical Radiation Physics, Department of Clinical Sciences, University of Lund, Skåne University Hospital, Malmö;

4. Department of Internal Medicine, Lasarettet Trelleborg, Trelleborg, Sweden

Abstract

Background Mounting collective radiation doses from computed tomography (CT) implies an increased risk of radiation-induced cancer in exposed populations, especially in the young. Purpose To evaluate radiation dose and image quality at 80-kVp CT to diagnose acute pulmonary embolism (PE) compared with a previous study at 100 and 120 kVp with all other scanning parameters unchanged. Material and Methods A custom-made chest phantom with a 12 mg I/mL-syringe was scanned at 80/100/ 120 kVp to evaluate relative changes in computed tomographic dose index (CTDIvol), attenuation, image noise, and contrast-to-noise ratio (CNR). Fifty patients underwent 80 kVp 16-row detector CT at 100 ‘Quality reference’ mAs. A total of 350 mg I/kg were injected to compensate for increased CNR at 80 kVp, while 300 mg I/kg had been used at 100/120 kVp. CTDIvol, dose-length product (DLP), and estimated effective dose were evaluated including Monte Carlo simulations. Pulmonary artery attenuation and noise were measured and CNR calculated. Two radiologists evaluated subjective image quality using a four-grade scale. Results Switching from 120 to 80 kVp in the phantom study decreased radiation dose by 67% while attenuation and noise increased 1.6 and 2.0 times, respectively, and CNR decreased by 16%. Switching from 120 to 80 kVp in the patient studies decreased estimated effective dose from 4.0 to 1.2 mSv (70% decrease) in median while pulmonary artery attenuation and noise roughly doubled from 332 to 653 HU and from 22 to 49 HU, respectively, resulting in similar CNR (13 vs. 12). At 80 kVp all examinations were regarded as adequate (8%) or excellent (92%). Conclusion Switching from 120 to 80 kVp CT without increased mAs but slightly increased iodine dose may be of special benefit to diagnose PE in younger individuals with preserved renal function where the primary aim is to minimize radiation dose and reaching levels below that of scintigraphy.

Publisher

SAGE Publications

Subject

Radiology, Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3