Breast compression in mammography: pressure distribution patterns

Author:

Dustler Magnus1,Andersson Ingvar2,Brorson Håkan3,Fröjd Patrik1,Mattsson Sören1,Tingberg Anders1,Zackrisson Sophia2,Förnvik Daniel1

Affiliation:

1. Medical Radiation Physics, Lund University, Skåne University Hospital, Malmö, Sweden

2. Diagnostic Centre of Imaging and Functional Medicine, Lund University, Skåne University Hospital, Malmö, Sweden

3. Plastic and Reconstructive Surgery, Department of Clinical Sciences Malmö, Lund University, Skåne University Hospital, Malmö, Sweden

Abstract

Background Breast compression is important in mammography in order to improve image quality, better separate tissue components, and reduce absorbed dose to the breast. In this study we use a method to measure and visualize the distribution of pressure over a compressed breast in mammography. Purpose To measure and describe the pressure distribution over the breast as a result of applied breast compression in mammography. Material and Methods One hundred and three women aged 40.7-74.3 years (median, 48.9 years) invited for mammographic screening consented to take part in this study. They were subjected to two additional breast compressions of the left breast (standard force and approximately 50% reduction). Pressure images of the compressed breast were obtained using force sensing resistor (FSR) sensors placed underneath the compression plate. Subjects rated their experience of pain on a visual analogue scale (VAS). Results Four pressure patterns were identified, fitting 81 of the 103 breasts, which were grouped accordingly. The remaining 22 breasts were found to correspond to a combination of any two patterns. Two groups (43 breasts) showed pressure mainly over the juxtathoracic part of the breast, had significantly greater breast thickness ( P = 0.003) and had a lower mean pressure over dense tissue ( P < 0.0001) than those with more evenly distributed pressure. Reducing compression force increased average breast thickness by 1.8 mm ( P < 0.0001). Conclusion The distribution of pressure differed greatly between breasts. In a large proportion of breasts the compression plate did not provide optimal compression of the breast, the compression force being absorbed in juxtathoracic structures.

Publisher

SAGE Publications

Subject

Radiology Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

Cited by 45 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3