Abstract
This chapter examined Fenton and sequencing batch reactor (SBR) treatment of pesticide industrial wastewater. The optimum operating conditions for Fenton pretreatment of the pesticide wastewater were H2O2/COD molar ratio 3.0, H2O2/Fe2+ molar ratio 10, pH 3 and reaction time 60 min. The COD and TOC removal were 58.51 and 39.76%, respectively and biodegradability (BOD5/COD ratio) increased from 0.02 to ~ 0.30 after 60 min reaction time. The reaction followed pseudo-first order kinetics with a rate constant (k) of 0.0083 min−1. In the post-treatment by aerobic SBR, five different Fenton operating conditions were investigated and H2O2/COD molar ratio 3.0, H2O2/Fe2+ molar ratio 25, pH 3 and reaction time 60 min appeared to be the most significant (p < 0.05) operating conditions. The Fenton–SBR treatment at 12 hr HRT achieved COD, TOC and BOD5 removal efficiency of 96.7, 97.7 and 93.3%, respectively. The Fenton-SBR process was effective for the treatment of pesticide wastewater.