Pecularities of Candida yeast identification by mass spectrometric analysis (MALDI-ToF MS)

Author:

Anisimova A. S.1ORCID,Poleeva M. V.1ORCID,Aronova N. V.1ORCID,Tsimbalistova M. V.1ORCID,Pavlovich N. V.1ORCID

Affiliation:

1. Federal State Health Institution «Rostov-on-Don Anti-Plague Institute» of the Federal Service for Supervision of Consumer Rights Protection and Human Welfare

Abstract

To carry the comparative analysis of sample preparation methods for the most effective identification of Candida yeast by mass spectrometric analysis. 265 strains of yeast and yeast-like fungi isolated from the sputum of patients with pneumonia were investigated. The selected strains were identified by conventional methods (cultural, morphological, tinctorial, enzymatic properties) and MALDI-ToF MS using the Autoflex speed III Bruker Daltonics mass spectrometer (Germany) and Flex Control software. To evaluate the effectiveness of fungi species determinination, the comparative analysis of sample preparation was performed using 4 methods: direct application to the target, an extended direct application method, protein extraction using ethanol/formic acid or trifluoroacetic acid. The accelerated scheme of identification of fungi by the culture method does not provide clear and unambiguous results. When using mass spectrometric analysis, the reliability of the results depended on the sample preparation. A comparative study of the effectiveness of fungi species determination by various methods of the sample preparation of 50 clinical isolates was carried out. It was revealed that the extraction of cells using TFC acid does not lead to the appearance of the recordable protein spectra. The use of direct and extended direct application methods made it possible to establish the species only in 32-44% of the strains. The most effective method of sample preparation was the method using formic acid and ethanol, which allowed us to determine the species affiliation in 100% of the studied fungi (Score 2.0). Depending on the yeast species, a high statistical indicator (Score≥2.3) was registered for 42-100% of samples. The results of present study show that the use of MALDI-ToF MS is the most reliable and informative method of Candida spp.identification.

Publisher

EKOlab

Subject

Biochemistry (medical),Medical Laboratory Technology,General Medicine

Reference15 articles.

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3