Clinical value of colonoscopy and positron emission tomography with computed tomography for colorectal cancer diagnosis

Author:

Nowicki Andrzej1,Kula Zbigniew2,Dobrzyń Paulina3

Affiliation:

1. Collegium Medicum in Bydgoszcz, Nicolaus Copernicus University in Torun Department of Oncology Nursing

2. Centrum Onkologii w Bydgoszczy Zakład Endoskopii Zakład Endoskopii Centrum Onkologii

3. Zakład Pielęgniarstwa Onkologicznego Collegium Medicum w Bydgoszczy Uniwersytet Mikołaja Kopernika w Toruniu

Abstract

Introduction: Colonoscopy and PET / CT are among the major diagnostic tests for colorectal cancer. The sensitivity, specificity, and accuracy of these studies are still being assessed differently. Objective: The aim of the study was to compare the sensitivity, specificity and accuracy of colonoscopy and PET / CT in the diagnosis of colorectal cancer. Material and methods: The medical records of 125 patients with colonoscopy and PET / CT in the years 2014-2015 were analyzed retrospectively. The research was done at the Professor Franciszek Łukaszczyk Oncology Center in Bydgoszcz. Based on the macroscopic description of colonoscopy, the results were divided into two groups: with and without probability of cancer. The average SUV value in PET / CT for colorectal cancer was calculated and without this diagnosis. The average value of SUV 14 and higher was considered probable, while 11 or less had no probability of cancer. Standardized mathematical formulas were used to evaluate the sensitivity, specificity and accuracy. Results: More than half of the patients - 78 (62.4%) were males. The majority of patients -42 (36.6%) were aged 65-74. The majority (106) (68.8%) were diagnosed as polyps and 24 (15.6%) as tumor-like lesions. Polyps were placed in the rectum -32 (30.2%), in the sigmoid colon - 26 (24.5%) and 15 (13.2%) in the ascending colon. Tumors were located in the rectum - 11 (45.8%) and 4 (16.7%) in the recto-sigmoid junction. 38 (24.6%) adenocarcinomas and 67 (43.5%) adenomas were diagnosed. The detection rate of RJG was 32% in colonoscopy and PET / CT. The sensitivity of the colonoscopy was 80%, the specificity - 68.4% and the accuracy - 71.4%. The sensitivity, specificity and accuracy of PET / CT were 65%, 75%, 4% and 72.7%, respectively. Conclusions: Colonoscopy has a higher sensitivity in colorectal cancer diagnosis, but specificity and accuracy are higher in PET / CT. Keywords: colorectal cancer, colonoscopy, PET / CT, sensitivity, specificity, accuracy

Publisher

Index Copernicus

Subject

General Medicine,Surgery

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3