Evaluation the results of electromagnetic compatibility of a prototype device for ear stimulation in patients with tinnitus

Author:

Olszewski Jurek1ORCID

Affiliation:

1. Clinic of Otolaryngology, Laryngological Oncology, Audiology and Phoniatrics at the 2nd Department of Otolaryngology of the Medical University of Lodz, Department of Polish Dialectology and Logopedics of the University of Lodz, Poland

Abstract

<b><br>Aim:</b> The aim of the study was to evaluate the results of electromagnetic compatibility of a prototype device for ear stimulation in patients with tinnitus.</br> <b><br>Material and methods:</b> The electromagnetic compatibility tests of the prototype device for electro- and magnetostimulation of the hearing organ were carried out at the Center for Attestation and Certification Tests OBAC Sp. z o. o. in Gliwice in 2020. The following product standards were used: PN-EN 60601-1-2:2015-11 – medical electrical equipment (general requirements for basic safety and essential functioning; PN-EN 55011:2012 - industrial, scientific and medical equipment [characteristics of radio frequency disturbances] ) PN-EN 61000-3-2:2014-10 – electromagnetic compatibility (EMC), permissible levels of harmonic current emissions (phase load current ≤ 16 A).</br> <b><br>Results:</b> The level of expanded uncertainty in the measurement of conducted disturbances in the range of 0.150–30MHz does not exceed the level specified in the PN-EN-55016-4-2:2011 standard. In the study of the emission of radiated disturbances up to 1GHz in the frequency range of 30–1000MHz (PN-EN 55011:2012 standard), it was found that the setting of the EUT during the tests was in accordance with the requirements of the standard. The level of expanded uncertainty in the measurement of radiated disturbances in the 30–1000MHz range does not exceed the level specified in the PN-EN 55016–4-2:2011 standard. The measured current harmonic levels (phase power supply current ≤16A) with a frequency range of 50Hz–2kHz do not exceed the permissible levels specified in the PN-EN 61000-3-2:2014-10 standard. The test of resistance to the magnetic field at the frequency of the power grid (PN-EN 61000-4-8: 2010 standard also showed that the setting of the EUT during the tests was in accordance with the requirements of the standard and the result was positive.</br> <b><br>Conclusions:</b> Testing of immunity to radiated radio frequency electromagnetic field (PN-EN 61000-4-3:2007 +A1:2008+A2:2011 standard) and testing of resistance to magnetic field at power frequency (PN-EN 61000-4-8 standard :2010) did not exceed the level specified in the standard and showed a positive result. The measured harmonic levels of the network current (phase supply current ≤16A) with the frequency range 50Hz–2kHz do not exceed the permissible levels specified in the PN-EN 61000- 3-2:2014-10 standard for a class A device.</br>

Publisher

Index Copernicus

Subject

Otorhinolaryngology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3