Abstract
Abstract
As the dominant shielding functional material, the permalloy sheet primarily determines the static and low-frequency shielding performances of magnetically shielded room (MSR). However, the lack of measurement of shielding sheets for practical use would lead to a non-negligible evaluation error in MSR performance. Therefore, an estimation technique of shielding factor (SF) and the remanence of MSR is proposed in this paper while considering the nonlinear magnetic characteristics of the permalloy sheet tested by a single sheet tester for low-frequency field and degaussing situation (L-D-SST). First, a high-accuracy measurement system, comprising L-D-SST (for exciting magnetic field and sensing the corresponding B and H) and the control system (for applying excitation to L-D-SST and amplifying, filtering, and collecting B and H signals), is established. Weak magnetic fields at low frequencies and decaying alternating demagnetizing field excitations are separately applied to the L-D-SST for basic magnetization curves (BM curves) and an anhysteretic magnetization curve (AM curve) tests. Furthermore, the BM and AM curves are respectively integrated with the FEM algorithm for accurate and reliable estimations of the SF and remanence of MSR in an operational state. In addition, the tested magnetic properties are applied for the optimization of MSR shielding quality.
Funder
National Natural Science Foundation of China
”Double first-class” guidance project