In the article, the processes of integrity loss of fire-retardant cladding from mineral wool of a steel I-beam are considered. The relation between fire-retardant cladding integrity and its thermal insulating ability was studied. Computer model of a steel beam with fire-retardant cladding of mineral wool, which takes into account its own weight, current mechanical load and temperature mode of heating under the heat-insulating effect of the cladding, using the computer system LS-DINA, is developed in this article. It is shown that the fire-retardant cladding loses its integrity under the thermal influence of fire long before the onset of the limit state of loss of fire resistance in terms of bearing capacity. The conditions under which fire-retardant cladding loses its integrity and fire-retardant ability are investigated. Having considered the time of fire-retardant cladding integrity loss the fire resistance limit can be significantly clarified and allows to avoid early collapse of building structures cause by fire.