Author:
Walsh R P,Radcliff K J,Lu J,Han K
Abstract
Abstract
Nitronic 40 forged shells are typically used for structural reinforcement in high field pulse magnet design and applications. To better understand the mechanical performance of this versatile high strength austenitic steel a series of mechanical tests were conducted. Tensile were performed at 295 K, 77 K and 4 K, and cryogenic fracture mechanics tests were performed at 77 K and 4 K. The effect of temperature on strength, ductility, toughness and fatigue crack growth rate are evaluated. Microstructure and composition effects are also presented and discussed.
Reference6 articles.
1. The U. S. NHMFL 60 T Long Pulse Magnet Failure;Sims;IEEE Transactions on Applied Superconductivity,2002
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献