Design and application of double layer bowtie antenna and single layer bowtie antenna as UHF sensors for partial discharge detection

Author:

Uwiringiyimana J P,Khayam U

Abstract

Abstract The reliability of the power system cannot be achieved without good insulation quality of the high voltage apparatus. The Ultra-high frequency (UHF) method has been applied and proven to be accurate in detecting partial discharge (PD) signals emitted from the PD source in the form of electromagnetic waves. This paper discusses the design and application of double layer bowtie antenna and single layer bowtie antenna as UHF sensors for partial discharge detection in air insulation. The PD measurement results obtained by using the designed double layer bowtie antenna were compared with PD measurement results obtained by using the single layer bowtie antenna. The PD characteristics of induced EM waves detected by double layer bowtie antenna and single layer bowtie have been analysed. Based on the simulation results, the double layer bowtie antenna has a minimum return loss values of -31.54 dB and -33.43 dB, with corresponding resonance frequency values of 1.7 GHz and 2.7 GHz, with a total bandwidth of 602 MHz, and corresponding VSWR values of 1.04 and 1.05 while the measurement results by using Vector Network Analyser (VNA) shows that the designed double layer bowtie antenna has a minimum return loss of -20.2 dB, at a resonance frequency of 1.7 GHz, a bandwidth of 576 MHz and corresponding VSWR of 1.2. The single layer bowtie antenna has a bandwidth of 240 MHz, a minimum return loss of -24 dB, at a resonance frequency of 1.28 GHz, and a VSWR of 1.13 based on the simulation results while the single layer bowtie antenna has a bandwidth of 298 MHz, a minimum return loss of -23.32 dB, at a resonance frequency of 1.3 GHz, and a VSWR of 1.14 based on the measurement results by using VNA. The bowtie antennas were designed using the 3D-HFSS software with FR4-epoxy substrate type and later on were printed on the Printed Circuit Board (PCB). The PD measurement data were performed by using the applied voltage level of 7 kV. According to the antennas simulation results, antennas measurement results by VNA and PD measurement results, the double layer bowtie antenna has proven to be more sensitive than the single layer bowtie antenna.

Publisher

IOP Publishing

Subject

General Medicine

Reference11 articles.

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3