Author:
Hmood K S,Pop H,Apostol V,Al Douri J,Al Qaisy S J,Badescu V
Abstract
Abstract
This paper presents a mathematical model to simulate the effect of the coiling diameter, subcooling degree and internal diameter on the characteristics flow of the refrigerants R1234yf and R600a, flowing through an adiabatic helical capillary tube. The homogeneous flow model was developed in the two-phase region based on the fundamentals of conservation of mass, momentum and fluid energy in the capillary tube. To validate this model, a comparison with numerical data on helical capillary tubes obtained by previous investigators has been made. It was reported that the coiling diameter, the inner diameter and inlet temperature of the capillary tube significantly influence on the pressure drop and quality and temperature distribution of the refrigerants R1234yf and R600a flowing inside the adiabatic helical tube. To validate this model, a comparison with numerical data on helical capillary tubes obtained by previous investigators has been made. Finally, the outcomes obtained from the present model exhibit satisfactory agreement with the available numerical data of helical capillary tubes.
Reference27 articles.
1. Local frictional pressure drop during vaporization of R-12 through capillary tubes;Lin;Int. J. of Multiphase Flow,1991
2. Performance of a split-type air conditioner matched with coiled adiabatic capillary tubes using HCFC22 and HC290;Zhou;Appl. Energy,2010
3. A Homogeneous Capillary Tube Model -Comprehensive Parameter Studies Using Isobutane As Refrigerant In;Heimel,2012
4. An Experimental Comparison of the Refrigerant Flow through Adiabatic and Non-Adiabatic Helical Capillary Tubes;Javidmand,2014
5. Experimental investigation on flow of R-600a inside a diabatic helically coiled capillary tube: Concentric configuration;Dubba;Int. J. Refrig.,2018
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献