Monitoring and Control of Cooler Tank Level Measurement In Gas Cleaning Plant (GCP)

Author:

Rajalakshmi P,Ponni Bala M,Aravind C,Suji Prasad S J

Abstract

Abstract The Cooler Tank Level plays a major role in Gas Cleaning Plants (GCP) and it is a very important parameter to be measured and controlled. If the tank level is not maintained in nominal range, the dust particles will accumulate on the Cooler Tank and affect the process. The production of copper metal at Vedanta, Thoothukudi include Blending of various grades of copper concentrates, Smelting and Refining. Sulphur dioxide is generated from during the smelting of copper and is converted to Sulphuric acid as a byproduct. This process involves three steps such as cleaning of sulphur dioxide gas from Furnace, Catalytic conversion of S02 to SO3 and amalgamation of SO3 with sulphuric acid. The conversion process is exothermic, reversible and adiabatic reaction and hence if the temperature increases it destroys the formation of sulphur trioxide. Hence in order to achieve high conversion efficiency, the converter gases need to be cooled. The SO2 gas from smelter contains metallic dust, fume, acid mist, water vapour and other impurities like halides which will contaminate the product. Therefore the gases are to be cooled and cleaned in Gas Cleaning Plant (GCP). Cooler tank used to remove water vapour from the gas and dust settle at the bottom of cooler. Cooler tank level needs to be maintained in order to avoid overflow of water into scrubber which will block the inlet gas. The level of cooler tank is to be continuously monitored and controlled to achieve the optimum results. The limitations of using Differential Pressure Transmitter for level measurement are overcome by ultrasonic based level sensor and automated using Distributed Control System and Human Machine Interface (HMI).

Publisher

IOP Publishing

Subject

General Medicine

Reference13 articles.

1. Petroleum Fractions Liquid-Vapor Equilibrium Simulation using Unisim Design;Patrascioiu;Rev. Chim.(Bucharest),2015

2. Fuzzy controller for adjustment of liquid level in the tank;Raduca;Annals of the University of Craiova-Mathematics and Computer Science Series,2011

3. Modeling and control of an interconnected combined cycle gas turbine using fuzzy and ANFIS controllers;Elhosseini;Electrical Engineering,2018

4. Microcontroller based automated water level sensing and controlling: design and implementation issue;Reza,2010

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Highly sensitive push-pull differential pressure sensor with multi-parameter measurement capabilities;Optics & Laser Technology;2025-02

2. Scientific evaluation of ultrasonic sensors for use in applications of water and hydraulic monitoring;Sensors and Smart Structures Technologies for Civil, Mechanical, and Aerospace Systems 2023;2023-04-18

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3