Abstract
Abstract
This paper is focused on the numerical analysis of an adaptive membrane structure, the model of which was created on the basis of experimental device in the lab. It was researched out the effect of asymmetric use of actuators on the membrane structure without structural loads. Results of the article describe the behaviour of numerical model. The results gained from numerical model will be compared in the future with the results measured out from the experimental device.