Author:
Fitrah Ridho Aidil,Nofriyandi R
Abstract
Abstract
Cold formed steel (CFS) is mostly used for short span structures in Indonesia because its advantages in cost and time efficiency. However, there is still limited number of long-span construction using cold formed steel because its buckling issue. Throughout the time, there are many researches that revealed the buckling issues can be prevented; one of them is combining their section. Then, CFS structure should give full structural performance. This research aims to analyze the performance of long-span roof truss, 24 m, using CFS back to back channel section. Two types of roof trusses, model 1 and model 2, are compared to get better configuration for long-span roof truss. Analysis is conducted by 2D model and analytically calculated based on SNI 7971:2013. The results are the maximum axial tensile force and axial compressive force, and also deflection. They will be compared to CFS back to back channel section capacity. This analysis obtained the stress ratio and deflection of both configurations. Based on analysis results, CFS back to back channel section safely withstands resisting axial forces by giving compressive ratio number around 0,54-0,72. Then, model 2 has given better structural performance, stress ratio and deflection, than model 1.
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献