Abstract
Abstract
There are many power equipments in the UHV valve hall, including the converter transformer, converter valve tower, all kinds of bushing, tubular bus. The operation condition monitoring of the above main equipment mainly includes electrical performance parameter measurement, oil and gas insulation medium performance parameter measurement and other means. This paper mainly introduces a monitoring method for the operation status of converter valve hall from the perspective of image processing technology. The technology mainly includes: 1) the application of intelligent image processing technology to identify and classify the database of infrared thermal imager and ultraviolet imager; 2) the real-time on-line measurement for the insulation distance of typical fittings through Kalman filter technology, including the measurement of the hottest temperature The insulation distance between partial discharge point and zero potential grounding point; 3) the electric field simulation model of typical main equipment in valve hall is established based on three-dimensional modeling technology of finite element method, and the surface electric field distribution of key main equipment fittings is obtained. Combined with the image database information, insulation distance information and typical main equipment electric field distribution information, the operation state parameters are effectively obtained, and the intelligent algorithm is applied to automatically evaluate its operation state, discover the latent fault and locate the positive fault, so as to provide effective data support and the protection strategy for the main equipment operation and maintenance.
Subject
General Physics and Astronomy
Reference15 articles.
1. Study on the harmonic losses of UHV converter transformer windings subject to non-sinusoidal load current[J];Liangxian;Proceedings of the CSEE,2014
2. Research on kernel technology of reactor in 1000kV AC transmission engineering[J];Chuan-long;Transformer,2009
3. Numerical computation of ohmic and eddy-current winding losses of converter transformers including higher harmonics of load current[J];Smajic;IEEE Transactions on Magnetics,2012
4. Analysis and countermeasure on typical external insulation failure of main equipments of ±500kV converter station[J];Jie;Power System Technology,2012
5. Study on electric field distribution of ±800 kV converting transformer bushing outlet terminal during polarity reversal test[J];Peng;Insulators and Surge Arresters,2009
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献