Research on intelligent mattress based on improved SMS structure sensing fiber

Author:

Ke Chenxi,Cai Yilun,Zhao Tao,Li Zhengying

Abstract

Abstract The contact-type vital signs detection system affects the user’s comfort and causes inconvenience due to its monitoring through skin contact. And most of the non-contact equipment precision is not high, or the cost is too high. To solve the above problems, this article is based on the physiological activity of slight vibration in multimode optical fiber micro bending deformation which results in the change of light intensity principle, considering the singlemode-multimode- singlemode(SMS) fiber of the structure of the sensor has simple structure, low cost, high sensitivity, but get the signal to noise is bigger, the accuracy is not high, this paper designs a kind of intelligent mattress based on modified SMS sensing optical fiber. The mattress can obtain ballistocardiogram signal in real time by changing the small light intensity, and obtain the heart rate, respiration rate and other information through the algorithm processing signal. In this design, the sensing fiber of the mattress is embedded in a small core fiber to solve the shortcomings of signal noise interference and instability obtained by the SMS structure fiber, and then it is embedded in the mattress by means of serpentine routing, and uses the covering material of the mattress adjusts the micro-bending period of the optical fiber to reach the critical mechanical period, so that the mattress has high sensitivity. Through in the laboratory and SMS type sensor for heart and breath signal are compared, and contrast and by Fast Fourier Transform (FFT) in frequency domain signal is analyzed, the vital signs of signal more clearly this mattress stable noise smaller, replace the tester for many times after tests, get the signal of high accuracy, the error is very small. The experiment shows that the mattress can detect non-sensory vital signs, facilitate the user to monitor his/her physical condition in real time in daily work and life, and timely inform the family members and medical staff in case of emergency, so as to avoid the occurrence of accidents.

Publisher

IOP Publishing

Subject

General Physics and Astronomy

Reference16 articles.

1. Noninvasive pulse oximetry utilizing skin reflectance photoplethysmography;Mendelson;IEEE Transactions on Biomedical Engineering,1988

2. Electrocardiogram (ECG) Biometric Authentication Using Pulse Active Ratio (PAR);Safie;IEEE Transactions on Information Forensics and Security,2011

3. Adaptive Beat-to-Beat Heart Rate Estimation in Ballistocardiograms;Bruser;IEEE Transactions on Information Technology in Biomedicine,2011

4. Methods of treating and diagnosing disease using biomarkers for bcg therapy:WIPO, WO2017059132A1[P];FAUSTMAN,2017

5. A novel measurement method for respiration rate by electromagnetic frequency sweep;Scalise

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3