Abstract
Abstract
Ground vibrations couple to the longitudinal and angular motion of the aLIGO test masses and limit the observatory sensitivity below 30 Hz. Novel inertial sensors have the potential to improve the aLIGO sensitivity in this band and simplify the lock acquisition of the detectors. In this paper, we experimentally study a compact 6D seismometer that consists of a mass suspended by a single wire. The position of the mass is interferometrically read out relative to the platform that supports the seismometer. We present the experimental results, discuss limitations of our metallic prototype, and show that a compact 6D seismometer made out of fused silica and suspended with a fused silica fibre has the potential to improve the aLIGO low frequency noise.
Funder
STFC
Institute for Gravitational Wave Astronomy at the University of Birmingham
STFC ‘Astrophysics at the University of Birmingham’ Grant ST
Subject
Physics and Astronomy (miscellaneous)