Author:
Yang X.,Heng Y.,Li Z.,Ma X.,Qian X.,Huang K.,Wu Z.,Xu M.,He W.,Pei Y.,Wang Y.
Abstract
Abstract
The Jiangmen Underground Neutrino Observatory (JUNO) Central
Detector (CD) is a huge acrylic spherical vessel containing 20,000
tons of liquid scintillator; the sphere is composed of 263 pieces of
acrylic spherical panels bonded by the mass polymerization. The
operation life time of the JUNO CD is 20 years. To ensure the
structural safety during the JUNO CD life time, the acrylic stress
of CD is required not to be greater than 3.5 MPa. The stresses of
acrylic spherical panels are required to be measured during the
installation on-site; unfortunately there is no suitable commercial
measurement equipment that can meet JUNO's requirements. Therefore,
a measurement setup based on photo-elastic principle and
spectrometric methods was designed, developed and tested for on-site
measurements. The measurement system performs accurate calibration
of stress-optical coefficient of acrylic in JUNO, and gives reliable
results of acrylic stresses. The measurement system has been tested
in the Taixing Donchamp Acrylic Ltd mechanical workshop, and the
achieved results meet the JUNO's requirements. The measurement
principle, the system components, and the tooling design are
introduced in the paper. Moreover, the calibration of stress-optical
coefficient of the acrylic and measurements results on JUNO acrylic
spherical panels are discussed in the following.