Validation of dual-energy CT-based composition analysis using fresh animal tissues and composition-optimized tissue equivalent samples

Author:

Niepel Katharina,Tattenberg Sebastian,Marants Raanan,Hu GuyueORCID,Bortfeld Thomas,Verburg Joost,Sudhyadhom AtcharORCID,Landry GuillaumeORCID,Parodi KatiaORCID

Abstract

Abstract Objective. Proton therapy allows for highly conformal dose deposition, but is sensitive to range uncertainties. Several approaches currently under development measure composition-dependent secondary radiation to monitor the delivered proton range in-vivo. To fully utilize these methods, an estimate of the elemental composition of the patient’s tissue is often needed. Approach. A published dual-energy computed tomography (DECT)-based composition-extraction algorithm was validated against reference compositions obtained with two independent methods. For this purpose, a set of phantoms containing either fresh porcine tissue or tissue-mimicking samples with known, realistic compositions were imaged with a CT scanner at two different energies. Then, the prompt gamma-ray (PG) signal during proton irradiation was measured with a PG detector prototype. The PG workflow used pre-calculated Monte Carlo simulations to obtain an optimized estimate of the sample’s carbon and oxygen contents. The compositions were also assessed with chemical combustion analysis (CCA), and the stopping-power ratio (SPR) was measured with a multi-layer ionization chamber. The DECT images were used to calculate SPR-, density- and elemental composition maps, and to assign voxel-wise compositions from a selection of human tissues. For a more comprehensive set of reference compositions, the original selection was extended by 135 additional tissues, corresponding to spongiosa, high-density bones and low-density tissues. Results. The root-mean-square error for the soft tissue carbon and oxygen content was 8.5 wt% and 9.5 wt% relative to the CCA result and 2.1 wt% and 10.3 wt% relative to the PG result. The phosphorous and calcium content were predicted within 0.4 wt% and 1.1 wt% of the CCA results, respectively. The largest discrepancies were encountered in samples whose composition deviated the most from tabulated compositions or that were more inhomogeneous. Significance. Overall, DECT-based composition estimations of relevant elements were in equal or better agreement with the ground truth than the established SECT-approach and could contribute to in-vivo dose verification measurements.

Funder

National Cancer Institute

Deutsche Forschungsgemeinschaft

National Institute of Biomedical Imaging and Bioengineering

Publisher

IOP Publishing

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3