Automated target placement for VMAT lattice radiation therapy: enhancing efficiency and consistency

Author:

Deufel Christopher,Dodoo Christopher,Kavanaugh James,Finley Randi,Lang Karen,Sorenson Kasie,Spreiter Sheri,Brooks Jamison,Moseley Douglas,Ahmed Safia K,Haddock Michael G,Ma Daniel,Park Sean S,Petersen Ivy A,Owen Dawn W,Grams Michael P

Abstract

Abstract Objective. An algorithm was developed for automated positioning of lattice points within volumetric modulated arc lattice radiation therapy (VMAT LRT) planning. These points are strategically placed within the gross tumor volume (GTV) to receive high doses, adhering to specific separation rules from adjacent organs at risk (OARs). The study goals included enhancing planning safety, consistency, and efficiency while emulating human performance. Approach. A Monte Carlo-based algorithm was designed to optimize the number and arrangement of lattice points within the GTV while considering placement constraints and objectives. These constraints encompassed minimum spacing between points, distance from OARs, and longitudinal separation along the z-axis. Additionally, the algorithm included an objective to permit, at the user’s discretion, solutions with more centrally placed lattice points within the GTV. To validate its effectiveness, the automated approach was compared with manually planned treatments for 24 previous patients. Prior to clinical implementation, a failure mode and effects analysis (FMEA) was conducted to identify potential shortcomings. Main results. The automated program successfully met all placement constraints with an average execution time (over 24 plans) of 0.29 ±0.07 min per lattice point. The average lattice point density (# points per 100 c.c. of GTV) was similar for automated (0.725) compared to manual placement (0.704). The dosimetric differences between the automated and manual plans were minimal, with statistically significant differences in certain metrics like minimum dose (1.9% versus 1.4%), D5% (52.8% versus 49.4%), D95% (7.1% versus 6.2%), and Body-GTV V30% (20.7 c.c. versus 19.7 c.c.). Significance. This study underscores the feasibility of employing a straightforward Monte Carlo-based algorithm to automate the creation of spherical target structures for VMAT LRT planning. The automated method yields similar dose metrics, enhances inter-planner consistency for larger targets, and requires fewer resources and less time compared to manual placement. This approach holds promise for standardizing treatment planning in prospective patient trials and facilitating its adoption across centers seeking to implement VMAT LRT techniques.

Publisher

IOP Publishing

Reference24 articles.

1. Safety and efficacy of lattice radiotherapy in voluminous non-small cell lung cancer;Amendola;Cureus,2019

2. A current review of spatial fractionation: back to the future?;Billena;Int. J. Radiat. Oncol. Biol. Phys.,2019

3. Evaluation of a commercially-available block for spatially fractionated radiation therapy;Buckey;J. Appl. Clin. Med. Phys.,2010

4. Clinical outcomes of spatially fractionated GRID radiotherapy in the treatment of bulky tumors of the head and neck;Choi;Cureus,2019

5. Spatially fractionated stereotactic body radiation therapy (Lattice) for large tumors;Duriseti;Adv. Radiat. Oncol.,2021

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3