Simultaneous needle catheter selection and dwell time optimization for preplanning of high-dose-rate brachytherapy of prostate cancer

Author:

Wang Chao,Gonzalez Yesenia,Shen ChenyangORCID,Hrycushko Brian,Jia Xun

Abstract

Abstract Purpose. Needle catheter positions critically affect the quality of treatment plans in prostate cancer high-dose-rate (HDR) brachytherapy. The current standard needle positioning approach is based on human intuition, which cannot guarantee a high-quality plan. This study proposed a method to simultaneously select needle catheter positions and determine dwell time for preplanning of HDR brachytherapy of prostate cancer. Methods. We formulated the needle catheter selection problem and inverse dwell time optimization problem in a unified framework. In addition to the dose objectives of the planning target volume (PTV) and organs at risk (OARs), the objective function incorporated a group-sparsity term with a needle-specific adaptive weighting scheme to generate high-quality plans with the minimal number of needle catheters. The optimization problem was solved by a fast-iterative shrinkage-thresholding algorithm. For validation purposes, we tested the proposed algorithm on 10 patient cases previously treated at our institution and compared the resulting plans with plans generated using needle catheters selected manually. Results. Compared to the plan with manually selected needle catheters, when normalizing both plans to the same PTV coverage V 100% = 95%, the plans generated by the proposed algorithm reduced median V 125% from 65% to 64%, but increased median V 150% from 35% to 38%, and V 200% from 14% to 16%. All planning objectives were met. All clinically important dosimetric parameters of OARs were reduced. D 1cc of bladder and rectum were reduced from 8.57 Gy to 8.50 Gy and from 7.24 Gy to 6.80 Gy, respectively. D max of urethra was reduced from 15.85 Gy to 15.77 Gy. The median number of selected needle catheters was reduced by two. The computational time for solving the proposed optimization problem was ∼90 s using MATLAB. Conclusion. The proposed algorithm was able to generate plans for prostate cancer HDR brachytherapy preplanning with increased median conformity index (0.73–0.77) and slightly lower median homogeneity index (0.64–0.62) with the number of selected needles reduced by two compared to the manual needle selection approach.

Publisher

IOP Publishing

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3