Reducing 4DCBCT scan time and dose through motion compensated acquisition and reconstruction

Author:

Lau Benjamin K F,Reynolds TessORCID,Wallis Andrew,Smith Sandie,George Armia,Keall Paul J,Sonke Jan-JakobORCID,Vinod Shalini K,Dillon Owen,O’Brien Ricky T

Abstract

Abstract Conventional 4DCBCT captures 1320 projections across 4 min. Adaptive 4DCBCT has been developed to reduce imaging dose and scan time. This study investigated reconstruction algorithms that best complement adaptive 4DCBCT acquisition for reducing imaging dose and scan time whilst maintaining or improving image quality compared to conventional 4DCBCT acquisition using real patient data from the first 10 adaptive 4DCBCT patients. Adaptive 4DCBCT was implemented in the ADaptive CT Acquisition for Personalized Thoracic imaging clinical trial. Adaptive 4DCBCT modulates gantry rotation speed and kV acquisition rate in response to the patient’s real-time respiratory signal, ensuring even angular spacing between projections at each respiratory phase. We examined the first 10 lung cancer radiotherapy patients that received adaptive 4DCBCT. Fast, 200-projection scans over 60–80 s, and slower, 600-projection scans over ∼240 s, were obtained after routine patient treatment and compared against conventional 4DCBCT acquisition. Adaptive 4DCBCT acquisitions were reconstructed using Feldkamp−Davis−Kress (FDK), McKinnon–Bates (MKB), Motion Compensated FDK (MCFDK) and Motion Compensated MKB (MCMKB) algorithms. Reconstructions were assessed via, Structural SIMilarity (SSIM), Signal-to-Noise-Ratio (SNR), Contrast-to-Noise-Ratio (CNR), Tissue Interface Sharpness of Diaphragm (TIS-D) and Tumor (TIS-T). The 200- and 600-projection adaptive 4DCBCT acquisition corresponded to 85% and 55% reduction in imaging dose, shorter and similar scan times of approximately 90 s and 236 s respectively, compared to conventional 4DCBCT acquisition. 200- and 600-projection adaptive 4DCBCT reconstructions achieved more than 0.900 SSIM relative to conventional 4DCBCT acquisition. Compared to conventional 4DCBCT acquisition, 200-projection adaptive 4DCBCT reconstructions achieved higher SNR, CNR, TIS-T, TIS-D with motion compensated algorithms, MCFDK (208%, 159%, 174%, 247%) and MCMKB (214%, 173%, 266%, 245%) respectively. The 200-projection adaptive 4DCBCT MCFDK- and MCMKB-reconstruction results show image quality improvements are possible even with 85% fewer projections acquired. We established acquisition-reconstruction protocols that provide substantial reductions in imaging time and dose whilst improving image quality.

Funder

Cancer Australia

National Health and Medical Research Council

Publisher

IOP Publishing

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3