Dosimetric evaluation of off-axis fields and angular transmission for the 1.5 T MR-linac

Author:

van den Dobbelsteen MORCID,Hackett S L,de Vries J H W,van Asselen B,Oolbekkink SORCID,Woodings S J,Raaymakers B W

Abstract

Abstract Objective. GPU-oriented Monte Carlo dose (GPUMCD) is a fast dose calculation algorithm used for treatment planning on the Unity MR-linac. Treatments for the MR-linac must be calculated quickly and accurately, and must account for two important MR-linac aspects: off-axis positions and angular transmission through the cryostat, couch and MR-coils. Therefore, the aim of this research is to quantify the system-related errors for GPUMCD calculations over the range of clinically-relevant field configurations and gantry angles. Approach. Dose profiles (crossline, inline and PDD) were measured and calculated for varying field sizes, off-axis positions and depths. Eleven different (off-axis) positions were included. The angular transmission was investigated by measuring and calculating the transmission for multiple angles, taking the cryostat, couch and coils into account. Main results. Differences between absolute point doses were found to be within 1.7% for field sizes 2 × 2 cm2 and larger. The relative dose profiles in the crossline, inline and PDD direction illustrated maximum mean dose differences of 0.9pp, 0.8pp and 0.7pp of D max in the central region for field sizes 2 × 2 cm2 and larger. The 1 × 1 cm2 field size showed larger dosimetric errors for absolute point doses and relative dose profiles. The maximum mean DTA in the penumbra was 0.7 mm. The mean difference in angular transmission ranged from −0.33% ± 0.60% to 0.27% ± 0.91% using three treatment machines. Additionally, 77.1%–93.7% of the datapoints remained within 1% transmission difference. The largest transmission differences were present at the edges of the table. Significance. This research showed that the GPUMCD algorithm provides reliable dose calculations with a low uncertainty for field sizes 2 × 2 cm2 and larger, focusing on off-axis fields and angular transmission.

Funder

Nederlandse Organisatie voor Wetenschappelijk Onderzoek

Publisher

IOP Publishing

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3