Author:
Hirai Ryusuke,Mori Shinichiro,Suyari Hiroki,Ishikawa Hitoshi
Abstract
Abstract
Objective. To improve respiratory gating accuracy and radiation treatment throughput, we developed a generalized model based on a deep neural network (DNN) for predicting any given patient’s respiratory motion. Approach. Our model uses long short-term memory (LSTM) based on a recurrent neural network (RNN), and improves upon common techniques. The first improvement is that the data input is not a one-dimensional sequence, but two-dimensional block data. This shortens the input sequence length, reducing computation time. Second, the output is not a scalar, but a sequence prediction. This increases the amount of available data, allowing improved prediction accuracy. For training and evaluation of our model, 434 sets of real-time position management data were retrospectively collected from clinical studies. The data were separated in a ratio of 4:1, with the larger set used for training models and the remaining set used for testing. We measured the accuracy of respiratory signal prediction and amplitude-based gating with prediction windows equaling 133, 333, and 533 ms. This new model was compared with the original LSTM and a non-recurrent DNN model. Main results. The mean absolute errors with the prediction window at 133, 333 and 533 ms were 0.036, 0.084, 0.119 with our model; 0.049, 0.14, 0.246 with the original LSTM-based model; and 0.041, 0.119, 0.16 with the non-recurrent DNN model, respectively. The computation time were 0.66 ms with our model; 0.63 ms the original LSTM-based model; 1.60 ms the non-recurrent DNN model, respectively. The accuracies of amplitude-based gating with the same prediction window settings and a duty cycle of approximately 50% were 98.3%, 95.8% and 92.7% with our model, 97.6%, 93.9% and 87.2% with the original LSTM-based model; and 97.9%, 94.3% and 89.5% with the non-recurrent DNN model, respectively. Significance. Our RNN algorithm for respiratory signal prediction successfully estimated tumor positions. We believe it will be useful in respiratory signal prediction technology.
Reference31 articles.
1. Neil houlsby an image is worth 16 × 16 words: transformers for image recognition at scale;Dosovitskiy,2020
2. Evaluation of respiratory movement during gated radiotherapy using film and electronic portal imaging;Ford;Int. J. Radiat. Oncol. Biol. Phys.,2002
3. Respiratory-gated PET/CT for pulmonary lesion characterisation-promises and problems;Frood;Br. J. Radiol.,2018
4. Respiratory gating for radiotherapy: main technical aspects and clinical benefits;Giraud;Bull. du Cancer,2010