Impact of contrast agents on organ dosimetry in pediatric diagnostic fluoroscopy: the voiding cystourethrogram

Author:

Smither Wyatt WORCID,Marshall Emily LORCID,Borrego DavidORCID,Applegate KimberlyORCID,Bolch Wesley EORCID

Abstract

Abstract Objective. International Commission on Radiological Protection (ICRP) Task Group 113 is developing reference values of organ and effective dose coefficients (DCs) for radiography, fluoroscopy, and computed tomography imaging exams. In support of these efforts, our focus is on pediatric diagnostic fluoroscopy. Contrast agents used during clinical examinations are an important consideration of the work undertaken by the Task Group. This work demonstrates the importance of including organ contrast volume concentrations for the calculation of reference organ DCs in the voiding cystourethrogram (VCUG). Approach. The ICRP newborn and 15 year female reference phantoms were utilized within the Particle and Heavy Ion Transport code system for the calculation of organ DCs. A pediatric radiologist with over 30 years of clinical experience defined the imaging fields for a VCUG examination consistent with clinical practice. Of these, four imaging fields were selected for investigation. The transport simulations modeled an iodinated contrast solution similar to Bracco Group’s 18% weight per volume, cystografin diatrizoate meglumine and typical bladder content was supplemented to make up the remainder volume. Iodinated contrast volumes of 0%, 25%, 50%, 75%, and 100% concentration by volume were modeled and associated DCs for in-field organs were computed. Main results. Organ DCs were calculated for the urinary bladder wall, colon wall, ovaries, and uterus for both female phantoms under irradiation geometries representative of a VCUG examination. Some organ DCs increased with iodine volume in the bladder and other organ DCs decreased as the iodine contrast volume completely filled the bladder (100%). Significance. The study results demonstrate for the newborn phantom percent differences in organ DCs varied between 0%–10% for the organs of interest, while they varied between 0%–22% in the 15 year phantom suggesting the importance of including contrast media in Monte Carlo radiation transport simulations of the VCUG examination.

Publisher

IOP Publishing

Reference20 articles.

1. American college of radiology (ACR)/society of pediatric radiology (SPR) practice parameter for the performance of fluoroscopic and songraphic voiding cystourethrography in children;ACR,2019

2. Radiation Protection No 185, European guidelines on diagnostic reference levels for paediatric imaging;European Commission,2018

3. Establishing a standard protocol for the voiding cystourethrography;Frimberger;Pediatrics,2016

4. Tungsten anode spectral model using interpolating cubic splines: unfiltered x-ray spectra from 20 kV to 640 kV;Hernandez;Med. Phys.,2014

5. Joint position statement and call for action for strengthening radaition protection of patients undergoing recurrent radiological imaging procedures;IAEA,2021

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3