Synthesis of pseudo-CT images from pelvic MRI images based on an MD-CycleGAN model for radiotherapy

Author:

Sun Hongfei,Xi Qianyi,Fan Rongbo,Sun JiaweiORCID,Xie Kai,Ni Xinye,Yang Jianhua

Abstract

Abstract Objective. A multi-discriminator-based cycle generative adversarial network (MD-CycleGAN) model is proposed to synthesize higher-quality pseudo-CT from MRI images. Approach. MRI and CT images obtained at the simulation stage with cervical cancer were selected to train the model. The generator adopted DenseNet as the main architecture. The local and global discriminators based on a convolutional neural network jointly discriminated the authenticity of the input image data. In the testing phase, the model was verified by a fourfold cross-validation method. In the prediction stage, the data were selected to evaluate the accuracy of the pseudo-CT in anatomy and dosimetry, and they were compared with the pseudo-CT synthesized by GAN with the generator based on the architectures of ResNet, sUNet, and FCN. Main results. There are significant differences (P < 0.05) in the fourfold cross-validation results on the peak signal-to-noise ratio and structural similarity index metrics between the pseudo-CT obtained based on MD-CycleGAN and the ground truth CT (CTgt). The pseudo-CT synthesized by MD-CycleGAN had closer anatomical information to the CTgt with a root mean square error of 47.83 ± 2.92 HU, a normalized mutual information value of 0.9014 ± 0.0212, and a mean absolute error value of 46.79 ± 2.76 HU. The differences in dose distribution between the pseudo-CT obtained by MD-CycleGAN and the CTgt were minimal. The mean absolute dose errors of Dosemax, Dosemin, and Dosemean based on the planning target volume were used to evaluate the dose uncertainty of the four pseudo-CT. The u-values of the Wilcoxon test were 55.407, 41.82, and 56.208, and the differences were statistically significant. The 2%/2 mm-based gamma pass rate (%) of the proposed method was 95.45 ± 1.91, and the comparison methods (ResNet_GAN, sUnet_GAN, and FCN_GAN) were 93.33 ± 1.20, 89.64 ± 1.63, and 87.31 ± 1.94, respectively. Significance. The pseudo-CT images obtained based on MD-CycleGAN have higher imaging quality and are closer to the CTgt in terms of anatomy and dosimetry than other GAN models.

Funder

Innovation Foundation for Doctor Dissertation of Northwestern Polytechnical University

Changzhou Key Laboratory of Medical Physics

General Program of Jiangsu Provincial Health Commission

Publisher

IOP Publishing

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3