Four-dimensional inverse-geometry computed tomography: a preliminary study

Author:

Kim Kyeong-Hyeon,Shin Dong-Seok,Kang Sang-Won,Kang Seong-Hee,Kim Tae-Ho,Chung Jin-Beom,Suh Tae Suk,Kim Dong-Su

Abstract

Abstract This study introduces and evaluates respiratory-correlated four-dimensional (4D) inverse geometry computed tomography (IGCT). The projection data of the IGCT were acquired in a single gantry rotation over 120 s. Three virtual phantoms—static Defrise, 4D Shepp–Logan, and 4D extended cardiac-torso (XCAT)—were used to obtain projection data for the IGCT and cone-beam computed tomography (CBCT). The projection acquisition parameters were determined to eliminate vacancies in the Radon space for an accurate rebinning process. Phase-based sorting was conducted within 10 phase bins, and the sorted projection data were binned into a cone beam geometry. Finally, Feldkamp–Davis–Kress reconstruction was conducted independently at each phase. The reconstructed images were compared using the structural similarity index measure (SSIM) and root mean square error (RMSE). The vertical profile of the Defrise reconstruction image was uniform, and the cone beam artefact was reduced in the IGCT image. Under an ideal projection acquisition condition, the mean coronal plane SSIMs of the Shepp–Logan and 4D XCAT phantoms were 0.899 and 0.706, respectively, which were higher than those of the CBCT (0.784 and 0.623, respectively). Similarly, the mean RMSEs of the coronal plane IGCT (0.036 and 0.158) exhibited an improvement over those of the CBCT (0.165 and 0.261, respectively). The mean standard deviations of the SSIM and RMSE were lower for IGCT than for CBCT. In particular, the SSIM and RMSE of the sagittal and coronal planes of the Shepp–Logan IGCT images were stable in all phase bins; however, those of the CBCT changed depending on the phase bins. Poor image quality was observed for IGCT under inappropriate conditions. This was caused by a vacancy in the Radon space, owing to an inappropriate scan setting. Overall, the proposed 4D IGCT exhibited better image quality than conventional CBCT.

Funder

the National Research Foundation of Korea

Publisher

IOP Publishing

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Differentiable Dynamic Visible-Light Tomography;SIGGRAPH Asia 2023 Conference Papers;2023-12-10

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3