The hemodynamic cardiac profiler volume-time curves and related parameters: an MRI validation study

Author:

Konings Maurits KORCID,Sharkawy Manuella Al,Verwijs Sjoerd MORCID,Bakermans Adrianus JORCID,Visscher Martijn,Hollenkamp Charles L,Veelo Denise P,Jørstad Harald TORCID

Abstract

Abstract Background. The hemodynamic cardiac profiler (HCP) is a new, non-invasive, operator-independent screening tool that uses six independent electrode pairs on the frontal thoracic skin, and a low-intensity, patient-safe, high-frequency applied alternating current to measure ventricular volume dynamics during the cardiac cycle for producing ventricular volume-time curves (VTCs). Objective. To validate VTCs from HCP against VTCs from MRI in healthy volunteers. Approach. Left- and right-ventricular VTCs were obtained by HCP and MRI in six healthy participants in supine position. Since HCP is not compatible with MRI, HCP measurements were performed within 20 min before and immediately after MRI, without intermittent fluid intake or release by participants. Intraclass correlation coefficients (ICCs) were calculated to validate HCP-VTC against MRI-VTC and to assess repeatability of HCP measurements before and after MRI. Bland–Altman plots were used to assess agreement between relevant HCP- and MRI-VTC-derived parameters. Precision of HCP’s measurement of VTC-derived parameters was determined for each study participant by calculating the coefficients of variation and repeatability coefficients. Main results. Left- and right-ventricular VTC ICCs between HCP and MRI were >0.8 for all study participants, indicating excellent agreement between HCP-VTCs and MRI-VTCs. Mean (range) ICC of HCP right-ventricular VTC versus MRI right-ventricular VTC was 0.94 (0.88–0.99) and seemed to be slightly higher than the mean ICC of HCP left-ventricular VTC versus MRI-VTC (0.91 (0.80–0.96)). The repeatability coefficient for HCP’s measurement of systolic time (tSys) was 45.0 ms at a mean value of 282.9 ± 26.3 ms. Repeatability of biventricular HCP-VTCs was excellent (ICC 0.96 (0.907–0.995)). Significance. Ventricular volume dynamics measured by HCP-VTCs show excellent agreement with VTCs measured by MRI. Since abnormal tSys is a sign of numerous cardiac diseases, the HCP may potentially be used as a diagnostic screening tool.

Publisher

IOP Publishing

Subject

Physiology (medical),Biomedical Engineering,Physiology,Biophysics

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3