Author:
Ning Guang-Sheng,Zhang Li-Min,Zhong Wei-Hua,Wang Sheng-Hong,Liu Xin-Yu,Wang Ding-Ping,He An-Ping,Liu Jian,Zhang Chang-Yi
Abstract
High purity SiC crystal was used as a passive monitor to measure neutron irradiation temperature in the 49-2 research reactor. The SiC monitors were irradiated with fast neutrons at elevated temperatures to 3.2 × 1020 n/cm2. The isochronal and isothermal annealing behaviors of the irradiated SiC were investigated by x-ray diffraction and four-point probe techniques. Invisible point defects and defect clusters are found to be the dominating defect types in the neutron-irradiated SiC. The amount of defect recovery in SiC reaches a maximum value after isothermal annealing for 30 min. Based on the annealing temperature dependences of both lattice swelling and material resistivity, the irradiation temperature of the SiC monitors is determined to be ∼410 °C, which is much higher than the thermocouple temperature of 275 °C recorded during neutron irradiation. The possible reasons for the difference are carefully discussed.
Subject
General Physics and Astronomy
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献