Abstract This paper presents a method of aerodynamic separation of supply-exhaust airflows in a supply and exhaust climate control unit for livestock facilities in order to minimize back suction. The air removed from livestock buildings contains a large amount of moisture, carbon dioxide, ammonia, hydrogen sulfide and other harmful gases and in mine units, the outlet and inlet openings are located close enough, which is why exhaust air can be sucked together with the supply air. The paper presents a set of measures to minimize back suction. In particular, the distance between the supply and exhaust openings is substantiated. Moreover, it was proposed to give an additional velocity to the exhaust air due to the energy of natural traction. In order to solve this problem, a nozzle with a convergence angle of 45 ° was installed at the outlet of the unit. The effectiveness of the proposed solution was tested experimentally and it was found that when the inlet and outlet openings were located at a distance of more than 0.5 m, as well as when the exhaust jet was given a velocity of 3 m / s, the amount of back suction did not exceed 5%.

Publisher

IOP Publishing

Subject

General Engineering

Reference7 articles.

1. Development of the experimental heat exchanger for obtaining energy from phasetransition water-ice;Ershova;International Transaction Journal of Engineering, Management and Applied Sciences and Technologies,2018

2. Mathematical modelling of processes of heat and mass transfer in channels of water evaporating coolers;Gulevsky;Journal of Physics: Conference Series,2018

3. Joint modelling of heat and mass transfer and aerodynamic processes in evaporative water coolers;Shatsky;Scientific Herald of the Voronezh State University of Architecture and Civil Engineering. Construction and Architecture,2012

4. To the question about work of water-evaporating coolers;Shatsky;Scientific Herald of the Voronezh State University of Architecture and Civil Engineering. Construction and Architecture,2009

5. Combined electric accumulation unit for air heating;Tikhomirov;Revista de la Universidad del Zulia,2019

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3