Heat transfer between heated, partially heated and non-heated residential units in buildings

Author:

Shesho Igor K.,Tashevski Done J.,Filkoski Risto V.

Abstract

Abstract Space heating cost allocation according to actual consumption can be one possible motivating factor for saving energy in residential and other buildings. As a consequence of the exclusion of a certain number of users in collective housing units from the central heating supply system in the city of Skopje, the problem of heating cost allocation and collection of the fixed part of the heat energy payment has arosen. The subject of the analysis in this study was the heat transfer in buildings, with the main focus on the issue of heat transfer rate between residential units with different internal temperatures, such as from heated to unheated or partly heated apartments in collective building objects. The purpose of the analysis was to assess the mutual energy interaction between the completely or partially excluded apartments from the central heating system and the adjacent apartments connected to the central heating system. This is done by simulating the thermal characteristics of typical buildings that are representatives of new (insulated) and old (un-insulated) buildings. For the simulation purposes, the external average daily and monthly temperatures were obtained based on the perennial outdoor temperatures measured in Skopje and additional series of input data that are characteristic for the city were used. For the value of the internal temperature in the dwellings the value for the standard internal design temperatures are predefined. As results of the simulation, values were obtained for the annual heat gains (in kWh/year) and the specific heat gains (in kWh/m2year) of the excluded apartments from the system of central heating through the enclosures (internal walls, ceiling and floor) of the adjacent apartments that are connected to the system for central heating and vertical hot water pipelines for an isolated and nonisolated buildings. In order to obtain a clearer picture, in the study are considered different configurations and positions of apartments in the building. As an indicator for each considered apartment, the ratio of the received thermal energy of the disconnected apartment to the required energy for its heating is calculated. Based on the obtained results, appropriate conclusions were drawn regarding the reduction of the necessary energy for heating of the excluded apartments, as a consequence of the thermal gains through the walls of the neighboring apartments that are connected to the heating system.

Publisher

IOP Publishing

Subject

General Engineering

Reference12 articles.

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3