Author:
Cheng Xiguang,Zhao Hongliang,Zhang Xu
Abstract
Abstract
In order to achieve accurate control of the audible sound of the acoustic parametric array in the air, fine phase control of the ultrasonic signal as a carrier is required. By establishing the parametric matrix mathematical model and the directivity function formula, the effects of delay accuracy on the ultrasonic carrier and the audible sound deflection angle are simulated and analyzed. The control of 16-channel phase-controlled parametric array excitation signal is realized by using the fast parallel processing speed of FPGA. The signal processing circuit is designed to D/A conversion and amplification of the parametric array excitation signal to drive the piezoelectric transducer array efficiently. The experimental results show that the system can achieve fine control of the parameter array carrier transmission delay. The control accuracy of the parametric array carrier for the 40KHz carrier is 1 ns, and the error delay is less than 1 ns.
Reference10 articles.
1. Parametric acoustic array[J];Westervelt;J. Acoust. Soc. Am.,1963
2. Research on FPGA Phased Array Phased Transmission System Based on FPGA [J];Luo;Instrument Technology and Sensor,2010
3. Research on STM32-based ultrasonic phased array blind guide system [J];Li;Modern Electronic Technology,2011
4. A reconfigurable arbitrary waveform generator using PWM modulation for ultrasound research [J];Assef;BioMedical Engineering OnLine,2013
5. Transcranial Histotripsy Therapy: A Feasibility Study [J];Kim;IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control,2014
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献