Abstract
Abstract
Image based diagnostics are interpreted in the context of spatial resolution. The same is true for tomographic image reconstruction. Current empirically driven approaches to quantify spatial resolution in chemical species tomography rely on a deterministic formulation based on point-spread functions which neglect the statistical prior information, that is integral to rank-deficient tomography. We propose a statistical spatial resolution measure based on the covariance of the reconstruction (point estimate). By demonstrating the resolution measure on a chemical species tomography test case, we show that the prior information acts as a lower limit for the spatial resolution. Furthermore, the spatial resolution measure can be employed for designing tomographic systems under consideration of spatial inhomogeneity of spatial resolution.
Funder
Natural Sciences and Engineering Research Council of Canada
Deutsche Forschungsgemeinschaft
Subject
Applied Mathematics,Instrumentation,Engineering (miscellaneous)