Abstract
Purpose
Flexible eddy current array (FECA) sensor is flexible and light in weight, which has broad application prospects in structural health monitoring. But, the sensor’s sensing channel number is more, increasing the added mass of sensor networks. This paper aims to reduce the sensing channel number by changing the sensing coil layout.
Design/methodology/approach
In this paper, FECA sensors with series sensing coil (SSC) layout and interactive sensing coil (ISC) layout are proposed, which reduce the number of sensor’s channels by half. Then, the variation of the output signal of the sensor when the crack expands along both sides of the hole is analyzed by simulation model. Finally, the fatigue crack monitoring experiment is carried out.
Findings
For the SSC layout, the simulation results show that the amplitude of each SSC group of the sensor increases when the crack propagates to the left or right. For the ISC layout, when the crack propagates on the right side of bolt hole, the induced voltage of each ISC group decreases. When the crack propagates on the left side of bolt hole, the induced voltage of each ISC group increases. The experiment results are consistent with simulation results, which verifies the correctness of simulation model. Compared with SSC layout, the ISC layout can judge the crack propagation direction. And the crack monitoring accuracy is 1 mm.
Originality/value
The research results provide a certain reference for reducing the number of sensor’s sensing channels. Results of the simulation and experiment show that the ISC layout can judge the crack propagation direction, and the crack monitoring accuracy is 1 mm.
Subject
Electrical and Electronic Engineering,Industrial and Manufacturing Engineering
Reference26 articles.
1. State-of-the-art in structural health monitoring for aeronautics,2008
2. Flexible eddy current sensor array for proximity sensing;Sensors and Actuators A: Physical,2007
3. Enhancements of eddy current testing techniques for quantitative nondestructive testing of key structural components of nuclear power plants;Nuclear Engineering and Design,2008
4. Inversion techniques for eddy current NDE using optimization strategies and a rapid 3D forward simulator;International Journal of Applied Electromagnetics & Mechanics,2004
5. An excitation coil layout method for improving the sensitivity of a rosette flexible eddy current array sensor;Smart Materials and Structures,2020
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献