Abstract
When attempts are made to use thin film anemometers in airflow to measure fluctuating velocity it is found that the dynamic sensitivity cannot be obtained from a steady-flow calibration. It is found that the dynamic sensitivity is considerably less than that predicted by static calibration and that the sensitivity is frequency-dependent. It is shown that thermal feedback from the substrate, on which the gauge is mounted, to the heated element is responsible for the variation of sensitivity with frequency, despite constant-temperature operation of the probe, and this variation is examined theoretically and experimentally.