Treatment planning comparison between high dose rate and intensity-modulated radiation therapy for prostate cancer as a means of boost dose

Author:

Bose Satya,Bahri Sanjeev,Lalonde Ron

Abstract

AbstractPurposeThe main objective of this study was to compare dosimetric characterisation of high-dose-rate brachytherapy (HDR-BT) with external beam intensity-modulated radiation therapy (EX-IMRT) as a means of delivering boost dose.Materials and methodsFive HDR patients were selected for IMRT planning. Patients underwent ultrasound-guided catheter placement for HDR. Computed tomography (CT) images were obtained and imported into the Nucletron PLATO Brachytherapy system. The prostate, urethra, bladder and rectum were contoured on axial slices. The dose was calculated and optimised by graphical optimisation. The CT images of these structures were exported from the PLATO to Eclipse workstation for IMRT planning. For each patient, the dose–volume histogram (DVH) of HDR and IMRT plans were generated, drawn on the same scale and compared.ResultsThe dose distribution in HDR plans was non-uniform and conformed peripherally inside the planned target volume (PTV). A small volume of the prostate received a very high dose from HDR.In IMRT plans, a uniform dose distribution was observed. The DVH curves for PTV dropped sharply and reached to a zero volume of the prostate at about 6·4 Gy. In HDR plans, the DVH curves for PTV showed a long tail up to a very high dose. About 10% of the prostate received about 13·3 Gy, which is 222% of the prescribed dose (6 Gy) in HDR plans. In contrast, the same volume in IMRT plans received <6 Gy (100%). The average dose for V90 was about 6·3 Gy for HDR and 5·8 Gy for IMRT plans. At a prostate volume of V100 level, the average dose in all plans was 5·0 Gy from HDR and 5·4 Gy from IMRT plans. In HDR plan, the V100 dose for urethra varied from 0·6 to 3·0 Gy (average 1·8 Gy). The range in IMRT plans varied from 3·6 to 6 Gy with an average of 4·7 Gy. At V90 level, the dose range in HDR and IMRT plans varied from 2·5 to 4·7 Gy (average 3·8 Gy) and 4·8 to 5·4 Gy (average 5·3 Gy), respectively. In general, the dose to the bladder and rectum was comparatively lower in HDR than in IMRT plans.ConclusionsHDR brachytherapy may reduce normal tissue toxicities in prostate boost treatments, even though the dose homogeneity inside the PTV is far worse than in IMRT treatments. Another advantage of HDR over IMRT is that the organ motion is not a significant concern as in IMRT.

Publisher

Cambridge University Press (CUP)

Subject

Oncology,Radiology Nuclear Medicine and imaging

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3