Quantitative Electron-Excited X-ray Microanalysis With Low-Energy L-shell X-ray Peaks Measured With Energy-Dispersive Spectrometry

Author:

Newbury Dale E.,Ritchie Nicholas W.M.

Abstract

Quantification of electron-exited X-ray spectra following the standards-based “k-ratio” (unknown/standard intensity) protocol with corrections for “matrix effects” (electron energy loss and backscattering, X-ray absorption, and secondary X-ray fluorescence) is a well-established method with a record of rigorous testing and extensive experience. Two recent studies by Gopon et al. working in the Fe–Si system and Llovet et al. working in the Ni–Si system have renewed interest in studying the accuracy of measurements made using L-shell X-ray peaks. Both have reported unexpectedly large deviations in analytical accuracy when analyzing intermetallic compounds when using the low photon energy Fe or Ni L-shell X-ray peaks with pure element standards and wavelength-dispersive X-ray spectrometry. This study confirms those observations on the Ni-based intermetallic compounds using energy-dispersive X-ray spectrometry and extends the study of analysis with low photon energy L-shell peaks to a wide range of elements, Ti to Se. Within this range of elements, anomalies in analytical accuracy have been found for Fe, Co, and Ge in addition to Ni. For these elements, the use of compound standards instead of pure elements usually resulted in significantly improved analytical accuracy. However, compound standards do not always provide satisfactory accuracy as is demonstrated for L-shell peak analysis in the Fe–S system: FeS and FeS2 unexpectedly do not provide good accuracy when used as mutual standards.

Publisher

Cambridge University Press (CUP)

Subject

Instrumentation

Reference21 articles.

1. Iterative procedures in electron probe analysis corrections

2. Solving the iron quantification problem in low-kV EPMA: An essential step toward improved analytical spatial resolution in electron probe microanalysis—Olivines

3. Castaing, R (1951). Application of electron probes to local chemical and crystallographic analysis. PhD Thesis. University of Paris.

4. ISO (2021). International Organization for Standardization, standard I. SO 22029:2003.

5. Exploring the limits of EDS microanalysis: rare earth element analyses

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3