Author:
Adhikari Srikar,Blaivas Michael,Lyon Matthew,Shiver Stephen
Abstract
AbstractObjectiveDisaster management is a complex and difficult undertaking that may involve limited health care resources and evaluation of multiple victims. The objectives of this study were to evaluate the feasibility of real-time ultrasound video transmission from a simulated disaster triage location via commercially available video mobile phones and assess the ability of emergency physicians to accurately interpret the transmitted video of Focused Assessment with Sonography for Trauma (FAST) ultrasound examinations.MethodsThis was a prospective, observational study that took place at a simulated disaster scene put on for an Advanced Disaster Life Support (ADLS) course. The second component occurred at a Level I academic urban emergency department (ED) with an annual census of 78,000. Nineteen subjects at a simulated disaster scene were scanned using a SonoSite Titan ultrasound system (Bothell, Washington USA). An off-the-shelf, basic, video-capable mobile phone was used to record each ultrasound examination; and then immediately transmit the videos to another mobile phone approximately 170 miles away. The transmitted video was received by three emergency physicians with hospital credentialing in emergency ultrasound. Each FAST examination video was assessed for pathology, such as free fluid. The reviewers graded the image quality and documented the overall confidence level regarding whether or not a complete and adequate examination was visualized. Spearman's rank correlation coefficient was used to examine the agreement between the reviewers and the sonologist who performed the ultrasound examinations.ResultsA total of 19 videos were transmitted. The median time for transmission of a video was 82.5 seconds (95% CI, 67.7 seconds-97.3 seconds). No video failed to transmit correctly on the first attempt. The image quality ratings for the three reviewers were 7.7, 7.5, and 7.4 on a 10-point Likert scale. There was a moderate agreement between the reviewers and sonologist in image quality rating and overall confidence level scores (rho = 0.6).ConclusionsReal-time portable ultrasound video transmission via commercially available video mobile phones from a simulated disaster triage location is feasible and emergency physicians were able to accurately interpret video of FAST ultrasound examinations.AdhikariS, BlaivasM, LyonM, ShiverS. Transfer of real-time ultrasound video of FAST examinations from a simulated disaster scene via a mobile phone. Prehosp Disaster Med. 2014;29(3):1-4.
Publisher
Cambridge University Press (CUP)
Subject
Emergency,Emergency Medicine
Cited by
20 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献