Can peripheral venous blood gases replace arterial blood gases in emergency department patients?

Author:

Rang Louise C.F.,Murray Heather E.,Wells George A.,MacGougan Cameron K.

Abstract

ABSTRACTObjective:To determine if peripheral venous blood gas values for pH, partial pressure of carbon dioxide (PCO2) and the resultant calculated bicarbonate (HCO3) predict arterial values accurately enough to replace them in a clinical setting.Methods:This prospective observational study was performed in a university tertiary care emergency department from June to December 1998. Patients requiring arterial blood gas analysis were enrolled and underwent simultaneous venous blood gas sampling. The following data were prospectively recorded: age, sex, presenting complaint, vital signs, oxygen saturation, sample times, number of attempts and indication for testing. Correlation coefficients and mean differences with 95% confidence intervals (CIs) were calculated for pH,PCO2and HCO3. A survey of 45 academic emergency physicians was performed to determine the minimal clinically important difference for each variable.Results:The 218 subjects ranged in age from 15 to 90 (mean 60.4) years. The 2 blood samples were drawn within 10 minutes of each other for 205 (96%) of the 214 patients for whom data on timing were available. Pearson’s product–moment correlation coefficients between arterial and venous values were as follows: pH, 0.913;PCO2, 0.921; and HCO3, 0.953. The mean differences (and 95% CIs) between arterial and venous samples were as follows: pH, 0.036 (0.030–0.042);PCO2, 6.0 (5.0–7.0) mm Hg; and HCO3, 1.5 (1.3–1.7) mEq/L. The mean differences (± 2 standard deviations) were greater than the minimum clinically important differences identified in the survey.Conclusions:Arterial and venous blood gas samples were strongly correlated, and there were only small differences between them. A survey of emergency physicians suggested that the differences are too large to allow for interchangeability of results; however, venous values may be valid if used in conjunction with a correction factor or for trending purposes.

Publisher

Springer Science and Business Media LLC

Subject

Emergency Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3