Abstract
AbstractThree-dimensional focused ion beam/scanning electron microscopy (FIB/SEM tomography) is currently an important technique to characterize in 3D a complex semiconductor device or a specific failure. However, the industrial context demands low turnaround time making the technique less useful. To make it more attractive, the following study focuses on a specific methodology going from sample preparation to the final volume reconstruction to reduce the global time analysis while keeping reliable results. The FIB/SEM parameters available will be first analyzed to acquire a relevant dataset in a reasonable time (few hours). Then, a new alignment strategy based on specific alignment marks [using tetraethoxylisane (TEOS) and Pt deposition] is proposed to improve the volume reconstruction speed. These points combined represent a considerable improvement regarding the reliability of the results and the time consumption (gain of factor 3). This method is then applied to various case studies illustrating the benefits of the FIB/SEM tomography technique such as the precise identification of the origin of 3D defects, or the capability to perform a virtual top-down deprocessing on soft material not possible by any mechanical solution.
Publisher
Cambridge University Press (CUP)
Reference10 articles.
1. Static vs. dynamic FIB/SEM methods for 3D modeling;Van Leer;Microsc Microanal,2007
2. 3D reconstruction and characterization of polycrystalline microstructures using a FIB–SEM system
3. Steigerwald M. (2003). New detection system for LEO FE-SEM. Oberkochen, Germany: Carl Zeiss. Available at www.zeiss.de.
4. Introduction to Focused Ion Beams
Cited by
13 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献