The impact of cataract progression on accuracy of intraocular lens power measurement

Author:

Leng Lin,Li Honglei,Yin MinORCID,Gao Han,Shao Ting,Long Keli

Abstract

Purpose The aim of this study was to assess the impact of cataract progression using the Haigis formula-calculated intraocular lens (IOL) power and investigate the accuracy of IOL power measured at different time points. Methods This prospective study was performed on 75 eyes of 75 patients who underwent uneventful cataract surgery. Preoperative ocular parameters including axial length (AL), keratometry (K), anterior chamber depth (ACD), corneal astigmatism, corrected distance visual acuity (CDVA) and uncorrected distance visual acuity (UDVA) examined at the two time points, more than 3 months preoperatively and preoperative 1 day were compared. The ocular parameters measured in the two time points were used to calculate the predicted implanted IOL power and the actual IOL power was chosen on the basis of parameters measured earlier before surgery using the Haigis formula. The mean numerical error (MNE) and mean absolute error (MAE) predicted by the two time points were also compared. Results There were significant differences in the ACD, IOL power, UDVA and CDVA (P<0.01), but no statistical differences in AL, mean K and corneal astigmatism (P>0.05) during the average of 5.6 months before surgery. No statistically significant difference was detected in MNE (P>0.05), while the MAE had a significant difference in the two time points (P<0.05). Conclusion The IOL power measured earlier before surgery might result in a higher accuracy and the postoperative refractive outcome tended towards emmetropia.

Funder

The Medical and Health Development Grant of Shandong Province, China

Publisher

Public Library of Science (PLoS)

Subject

Multidisciplinary

Reference32 articles.

1. Visual outcome of cataract surgery; study from the european registry of quality outcomes for cataract and refractive surgery;M Lundström;J Cataract Refract Surg,2013

2. Use of the Posterior/Anterior Corneal Curvature Radii Ratio to Improve the Accuracy of Intraocular Lens Power Calculation: Eom’s Adjustment Method;Kim Mingue;Invest. Ophthalmol. Vis. Sci,2018

3. Assessment of the accuracy of new and updated intraocular lens power calculation formulas in 10 930 eyes from the UK National Health Service;Darcy Kieren;J Cataract Refract Surg,2020

4. Sources of error in intraocular lens power calculation;S Norrby;J Cataract Refract Surg,2008

5. Protocols for studies of intraocular lens formula accuracy;J Hoffer Kenneth;Am. J. Ophthalmol,2015