Abstract
Background
This study examined the correlation of classroom ventilation (air exchanges per hour (ACH)) and exposure to CO2 ≥1,000 ppm with the incidence of SARS-CoV-2 over a 20-month period in a specialized school for students with intellectual and developmental disabilities (IDD). These students were at a higher risk of respiratory infection from SARS-CoV-2 due to challenges in tolerating mitigation measures (e.g. masking). One in-school measure proposed to help mitigate the risk of SARS-CoV-2 infection in schools is increased ventilation.
Methods
We established a community-engaged research partnership between the University of Rochester and the Mary Cariola Center school for students with IDD. Ambient CO2 levels were measured in 100 school rooms, and air changes per hour (ACH) were calculated. The number of SARS-CoV-2 cases for each room was collected over 20 months.
Results
97% of rooms had an estimated ACH ≤4.0, with 7% having CO2 levels ≥2,000 ppm for up to 3 hours per school day. A statistically significant correlation was found between the time that a room had CO2 levels ≥1,000 ppm and SARS-CoV-2 PCR tests normalized to room occupancy, accounting for 43% of the variance. No statistically significant correlation was found for room ACH and per-room SARS-CoV-2 cases. Rooms with ventilation systems using MERV-13 filters had lower SARS-CoV-2-positive PCR counts. These findings led to ongoing efforts to upgrade the ventilation systems in this community-engaged research project.
Conclusions
There was a statistically significant correlation between the total time of room CO2 concentrations ≥1,000 and SARS-CoV-2 cases in an IDD school. Merv-13 filters appear to decrease the incidence of SARS-CoV-2 infection. This research partnership identified areas for improving in-school ventilation.
Funder
Eunice Kennedy Shriver National Institute of Child Health and Human Development
National Center for Advancing Translational Sciences
Publisher
Public Library of Science (PLoS)
Reference65 articles.
1. Targeted reduction of airborne viral transmission risk in long-term residential aged care;A Brass;Age Ageing,2022
2. Centers for Disease Control and Prevention. Ventilation in Buildings and Vehicles to Prevent the Spread of COVID-19; 2021. CDC website. Available from: https://www.cdc.gov/coronavirus/2019-ncov/community/schools-childcare/ventilation.html.
3. Increasing ventilation reduces SARS-CoV-2 airborne transmission in schools: A retrospective cohort study in Italy’s Marche region;G Buonanno;Frontiers in Public Health,2022
4. An overview of the effect of bioaerosol size in coronavirus disease 2019 transmission;MI Guzman;The International Journal of Health Planning and Management,2021
5. ANSI/ASHRAE standard 62.1-2022: Ventilation for acceptable indoor air quality. Atlanta, GA: American Society of Heating, Refrigerating, and Air Conditioning Engineers; 2022.
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献