Rapid diagnosis and reduced workload for urinary tract infection using flowcytometry combined with direct antibiotic susceptibility testing

Author:

Gilboe Hanne MargretheORCID,Reiakvam Olaug Marie,Aasen Linda,Tjade Trygve,Bjerner Johan,Ranheim Trond Egil,Gaustad PeterORCID

Abstract

Background We evaluated if flowcytometry, using Sysmex UF-5000, could improve diagnosis of urinary tract infections by rapid identification of culture negative and contaminated samples prior to culture plating, thus reducing culture plating workload and response time. We also evaluated if it is possible to reduce the response time for antibiotic susceptibility profiles using the bacteria information flag on Sysmex UF-5000 to differentiate between Gram positive and negative bacteria, followed by direct Antibiotic Susceptibility Testing (dAST) on the positive urine samples. Methods One thousand urine samples were analyzed for bacteria, white blood cells and squamous cells by flowcytometry before culture plating. Results from flowcytometric analysis at different cut-off values were compared to results of culture plating. We evaluated dAST on 100 urine samples that were analyzed as positive by flowcytometry, containing either Gram positive or Gram negative bacteria. Results Using a cut-off value with bacterial count ≥100.000/mL and WBCs ≥10/μL, flowcytometry predicted 42,1% of samples with non-significant growth. We found that most contaminated samples contain few squamous cells. For 52/56 positive samples containing Gram negative bacteria dAST was identical to routine testing. Overall, there was concordance in 555/560 tested antibiotic combinations. Conclusion Flowcytometry offers advantages for diagnosis of urinary tract infections. Screening for negative urine samples on the day of arrival reduces culture plating and workload, and results in shorter response time for the negative samples. The bacteria information flag predicts positive samples containing Gram negative bacteria for dAST with high accuracy, thus Antibiotic Susceptibility Profile can be reported the day after arrival. For the positive samples containing Gram negative bacteria the concordance was very good between dAST and Antibiotic Susceptibility Testing in routine. For positive samples containing Gram positive bacteria the results were not convincing. We did not find any correlation between epithelial cells and contamination.

Publisher

Public Library of Science (PLoS)

Subject

Multidisciplinary

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3