Multiple-bead assay for the differential serodiagnosis of neglected human cestodiases: Neurocysticercosis and cystic echinococcosis

Author:

Hernández-González Ana,González-Bertolín BelénORCID,Urrea Laura,Fleury Agnes,Ferrer ElizabethORCID,Siles-Lucas Mar,Tamarozzi FrancescaORCID,Perteguer Maria J.ORCID

Abstract

Background Neurocysticercosis (NCC), and cystic echinococcosis (CE) are two neglected diseases caused by cestodes, co-endemic in many areas of the world. Imaging studies and serological tests are used in the diagnosis of both parasitic diseases, but cross-reactions may confound the results of the latter. The novel multiplex bead-based assay with recombinant antigens has been reported to increases the diagnostic accuracy of serological techniques. Methodology We set-up an immunoassay based on the multiplex bead-based platform (MBA), using the rT24H (against Cysticercus cellulosae, causing cysticercosis) and r2B2t (against Echinococcus granulosus sensu lato, causing CE) recombinant antigens, for simultaneous and differential diagnosis of these infections. The antigens were tested on 356 sera from 151 patients with CE, 126 patients with NCC, and 79 individuals negative for both diseases. Specificity was calculated including sera from healthy donors, other neurological diseases and the respective NCC or CE sera counterpart. The diagnostic accuracy of this assay was compared with two commercial ELISA tests, Novalisa and Ridascreen, widely used in the routine diagnosis of cysticercosis and CE, respectively. Main findings For the diagnosis of NCC, sensitivity ranged from 57.94–63.49% for the rT24H-MBA, and 40.48–46.03% for Novalisa ELISA depending on exclusion or inclusion of sera having equivocal results on ELISA from the analysis; specificities ranged from 90.87–91.30% and 70.43–76.96%, respectively. AUC values of the ROC curve were 0.783 (rT24H) and 0.619 (Novalisa) (p-value < 0.001). For the diagnosis of CE, the sensitivity of the r2B2t-MBA ranged from 68.87–69.77% and of Ridascreen ELISA from 50.00–57.62%; specificities from 92.47–92.68% and from 74.15–80.98%, respectively. AUC values were 0.717 and 0.760, respectively. Conclusions/Significance Overall, the recombinant antigens tested with the bead-based technology showed better diagnostic accuracy than the commercial assays, particularly for the diagnosis of NCC. The possibility of testing the same serum sample simultaneously for the presence of antibodies against both antigens is an added value particularly in seroprevalence studies for cysticercosis linked to control programs in endemic areas where these two parasites coexist.

Funder

Instituto de Salud Carlos III

Fundación Rafael Folch

Publisher

Public Library of Science (PLoS)

Subject

Infectious Diseases,Public Health, Environmental and Occupational Health

Reference47 articles.

1. Epidemiology of taeniosis/cysticercosis in Europe, a systematic review: Eastern Europe.;C Trevisan;Parasites and Vectors. BioMed Central Ltd.,2018

2. Epidemiology of taeniosis/cysticercosis in Europe, a systematic review: Western Europe.;M Laranjo-González;Parasit Vectors,2017

3. Control of cystic echinococcosis: Background and prospects.;E Larrieu;Zoonoses Public Health,2019

4. Echinococcosis: Advances in the 21st century;H Wen;Clin Microbiol Rev,2019

5. The monetary burden of cysticercosis in Mexico.;R Bhattarai;PLoS Negl Trop Dis,2019

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3