Background and objectives A key step in electrocardiogram (ECG) analysis is the detection of QRS complexes, particularly for arrhythmia detection. Telehealth ECGs present a new challenge for automated analysis as they are noisier than traditional clinical ECGs. The aim of this study was to identify the best-performing open-source QRS detector for use with telehealth ECGs. Methods The performance of 18 open-source QRS detectors was assessed on six datasets. These included four datasets of ECGs collected under supervision, and two datasets of telehealth ECGs collected without clinical supervision. The telehealth ECGs, consisting of single-lead ECGs recorded between the hands, included a novel dataset of 479 ECGs collected in the SAFER study of screening for atrial fibrillation (AF). Performance was assessed against manual annotations. Results A total of 12 QRS detectors performed well on ECGs collected under clinical supervision (F1 score ≥0.96). However, fewer performed well on telehealth ECGs: five performed well on the TELE ECG Database; six performed well on high-quality SAFER data; and performance was poorer on low-quality SAFER data (three QRS detectors achieved F1 of 0.78-0.84). The presence of AF had little impact on performance. Conclusions The Neurokit and University of New South Wales QRS detectors performed best in this study. These performed sufficiently well on high-quality telehealth ECGs, but not on low-quality ECGs. This demonstrates the need to handle low-quality ECGs appropriately to ensure only ECGs which can be accurately analysed are used for clinical decision making.

Funder

British Heart Foundation

National Institute for Health and Care Research

Publisher

Public Library of Science (PLoS)

Reference43 articles.

1. Mobile health applications for the detection of atrial fibrillation: a systematic review;CR Lopez Perales;EP Europace,2021

2. Wearable health devices in health care: narrative systematic review;L Lu;JMIR mHealth and uHealth,2020

3. Opportunities and challenges for contactless healthcare services in the post-COVID-19 Era;SM Lee;Technol Forecast Soc Change,2021

4. QRS detection algorithm for telehealth electrocardiogram recordings;H Khamis;IEEE Trans Biomed Eng,2016

5. Performance analysis of ten common QRS detectors on different ECG application cases;F Liu;J Healthcare Eng,2018

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3