New chest compression method in infant resuscitation: Cross thumb technique

Author:

Jeon WoochanORCID,Kim JungeonORCID,Ko Yura,Lee JisookORCID

Abstract

Background The two-thumb encircling technique (2TT) is superior to the two-finger technique (2FT) in infant cardiopulmonary resuscitation (CPR), but there are difficulties in providing ventilation as soon as possible. We modified the 2TT to the cross-thumb technique (CTT) to maintain good CPR performance at the same position as 2FT. We aimed to compare the quality of chest compression and brief hands-off times in 2FT, 2TT, and CTT by a single rescuer using an infant CPR manikin model. Methods This study was designed as a prospective randomized controlled simulation-based study. We used the Resusci® Baby QCPR (Laerdal Medical, Stavanger, Norway) as a simulated 3-month-old infant. Ventilation was performed by the mouth-to-mouth technique using a chest compression-to-ventilation ratio of 30:2 as a single rescuer. Data on CPR quality, such as locations, rates, depth and release of chest compressions, hands-off times, and proper ventilation, were recorded using the Resusci® Baby QCPR and SkillReporter. Also, the chest compression fraction (CCF) was automatically calculated. Results The depth of chest compression in 2FT, 2TT, and CTT were 40.0 mm (interquartile range [IQR] 39.0, 41.0), 42.0 mm (IQR 41.0, 43.0), and 42.0 mm (IQR 41.0, 43.0), respectively. The depth of chest compression in 2FT was shallower than that in the other two techniques (P<0.05). CCF in 2FT, 2TT, and CTT were 73.9% (IQR 72.2, 75.6), 71.2% (IQR 67.2, 72.2) and 71.3% (IQR 67.7, 74.1), respectively. CCF was higher in 2FT than in the other two techniques (P<0.05). Correct location in 2FT, 2TT, and CTT were 99.0% (IQR 86.0, 100.0), 100.0% (IQR 97.0, 100.0) and 100.0% (IQR 99.0, 100.0), respectively. Correct location in CTT and 2TT was higher than that in 2FT. Performing CTT, the subjective pain and fatigue score were lower than other two technique. Conclusion A new chest compression technique, CTT was better in chest compression depth compared with 2FT and may be helpful in maintaining correct chest compression location with less pain and fatigue in infant CPR.

Funder

Inje University

Publisher

Public Library of Science (PLoS)

Subject

Multidisciplinary

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3