Variation in aorta attenuation in contrast-enhanced CT and its implications for calcification thresholds

Author:

Holcombe Sven A.ORCID,Horbal Steven R.ORCID,Ross Brian E.,Brown Edward,Derstine Brian A.ORCID,Wang Stewart C.

Abstract

Background CT contrast media improves vessel visualization but can also confound calcification measurements. We evaluated variance in aorta attenuation from varied contrast-enhancement scans, and quantified expected plaque detection errors when thresholding for calcification. Methods We measured aorta attenuation (AoHU) in central vessel regions from 10K abdominal CT scans and report AoHU relationships to contrast phase (non-contrast, arterial, venous, delayed), demographic variables (age, sex, weight), body location, and scan slice thickness. We also report expected plaque segmentation false-negative errors (plaque pixels misidentified as non-plaque pixels) and false-positive errors (vessel pixels falsely identified as plaque), comparing a uniform thresholding approach and a dynamic approach based on local mean/SD aorta attenuation. Results Females had higher AoHU than males in contrast-enhanced scans by 65/22/20 HU for arterial/venous/delayed phases (p < 0.001) but not in non-contrast scans (p > 0.05). Weight was negatively correlated with AoHU by 2.3HU/10kg but other predictors explained only small portions of intra-cohort variance (R2 < 0.1 in contrast-enhanced scans). Average AoHU differed by contrast phase, but considerable overlap was seen between distributions. Increasing uniform plaque thresholds from 130HU to 200HU/300HU/400HU produces respective false-negative plaque content losses of 35%/60%/75% from all scans with corresponding false-positive errors in arterial-phase scans of 95%/60%/15%. Dynamic segmentation at 3SD above mean AoHU reduces false-positive errors to 0.13% and false-negative errors to 8%, 25%, and 70% in delayed, venous, and arterial scans, respectively. Conclusion CT contrast produces heterogeneous aortic enhancements not readily determined by demographic or scan protocol factors. Uniform CT thresholds for calcified plaques incur high rates of pixel classification errors in contrast-enhanced scans which can be minimized using dynamic thresholds based on local aorta attenuation. Care should be taken to address these errors and sex-based biases in baseline attenuation when designing automatic calcification detection algorithms intended for broad use in contrast-enhanced CTs.

Publisher

Public Library of Science (PLoS)

Subject

Multidisciplinary

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3