Ultrasound insonation angle and scanning imaging modes for imaging dental implant structures: A benchtop study

Author:

Kripfgans Oliver D.,Goli Nikhila Devi,Majzoub Jad,De Siqueira Rafael Amorim CavalcantiORCID,Soki Fabiana,Chan Hsun-LiangORCID

Abstract

Introduction High frequency ultrasound has shown as a promising imaging modality to evaluate peri-implant tissues. It is not known if the ultrasound imaging settings might influence ultrasound’s ability to differentiate implant structures. The aim of this benchtop study was to evaluate the dependence of ultrasound on imaging angles and modes to measure implant geometry-related parameters. Methods A clinical ultrasound scanner (ZS3, Mindray) with an intraoral probe (L30-8) offering combinations of harmonic and compound imaging modes was employed for imaging 16 abutments and 4 implants. The samples were mounted to a micro-positioning system in a water tank, which allowed a range of -30 to 30-degree imaging angles in 5-degree increment between the probe and samples. The abutment angle, implant thread pitch and depth were measured on ultrasound, compared to the reference readings. The errors were computed as a function of the image angles and modes. All samples were replicated 3 times for 3 image modes and 11 image angles, thus resulting in 2,340 images. Results The mean errors of ultrasound to estimate 16 abutment angles, compared to the reference values, were between -1.8 to 2.7 degrees. The root mean squared error (RMSE) ranged from 1.5 to 4.6 degrees. Ultrasound significantly overestimated the thread pitch by 26.1 μm to 36.2 μm. The error in thread depth measurements were in a range of -50.5 μm to 39.6 μm, respectively. The RMSE of thread pitch and depth of the tested 4 implants was in a range of 34.7 to 56.9 μm and 51.0 to 101.8 μm, respectively. In most samples, these errors were independent of the image angle and modes. Conclusions Within the limitations of this study, high-frequency ultrasound was feasible in imaging abutments and implant fixtures independent of scanning angle within ±30° of normal incidence and for compounding and non-compounding-based imaging modes.

Funder

National Institutes of Health

Publisher

Public Library of Science (PLoS)

Subject

Multidisciplinary

Reference38 articles.

1. Introduction to dental implant;R. Palmer;British dental journal,1999

2. The management of peri-implant breakdown around functioning osseointegrated dental implants;SA Jovanovic;J Periodontol,1993

3. Peri-implant mucositis and peri-implantitis: clinical and histopathological characteristics and treatment;RA Khammissa;SADJ,2012

4. An insight into peri-implantitis: a systematic literature review.;V. Wilson;Primary dental journal,2013

5. Modern dental imaging: a review of the current technology and clinical applications in dental practice.;B Vandenberghe;European radiology.,2010

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3